G ENERAL M ETER S PECIFICATIONS
1. DISPLAY : 3 1/2-digit, 0.56" (14.2 mm) high, 7-segment red LED, (-) minus
sign displayed when current or voltage is negative. Decimal points inserted
before 1st, 2nd, or 3rd least significant digits by DIP switch selection.
2. POWER : 115/230 VAC, switch selectable. Allowable power line variation
±10%, 50/60 Hz, 6 VA.
Isolation : 2300 Vrms for 1 min. between input and supply
Working Voltage : 300 V max. , CAT II
3. INPUT RANGES/RESOLUTION : (Selectable by jumper connections.):
AC Voltmeters AC Current Meters DC Voltmeters DC Current Meters
0-1.999 V/1 mV 0-199.9 μA/0.1 μA        ?1.999 V/1 mV         ?199.9 μA/0.1 μA
0-19.99 V/10 mV 0-1.999 mA/1 μA          ?19.99 V/10 mV       ?1.999 mA/1 μA
0-199.9 V/100 mV 0-19.99 mA/10 μA        ?199.9 V/100 mV    ?19.99 mA/10 μA
0-300 V/1 V 0-199.9 mA/100 μA      ?300 V/1 V                ?199.9 mA/100 μA
0-1.999 A/1 mA ? 1.999 A/1 mA
0-199.9 mV/100 μ V ? 199.9 mV/100 μ V
Input Impedance:
Voltage : All ranges1M ?
Current : 199.9 μ A 1000.1 K ?
1.999 mA 100.1 ?
19.99 mA 10.1 ?
199.9 mA 1.1 ?
1.999 A 0.1 ?
Working Voltage : 300 V max., CAT II
4. ACCURACY :
AC Voltmeters : ±(0.1% of Reading + 3 digits) (45-500 Hz)
AC Current Meters (45-500 Hz):
199.9 μ A/199.9 mV, 1.999 mA, 19.99 mA : ±(0.1% of Reading + 3 digits)
199.9 mA : ±(0.15% of Reading + 3 digits)
1 A : ±(0.5% of Reading + 3 digits)
DC Voltmeters : ±(0.1% of Reading + 1 digit)
DC Current Meters :
199.9 μ A/199.9 mV, 1.999 mA, 19.99 mA : ±(0.1% of Reading + 1 digit)
199.9 mA : ±(0.15% of Reading + 1 digit)
1.999 A : ±(0.5% of Reading + 1 digit)
Note: Any individual range may be recalibrated (scaled) to 0.1% accuracy
with appropriate calibration equipment.
5. OVER-RANGE INDICATION : on all modes is indicated by blanking 3
least significant digits.
6. MAX. VOLTAGE ON LOWEST INPUT RANGE : 75 VAC or DC (Both
voltmeters and current meters).
7. MAX. VOLTAGE ON TERMINAL BLOCK : 300 VAC or DC (Both
voltmeters and current meters).
8. MAX. CURRENTS (FOR CURRENT METERS) :
199.9 μ A through 19.99 mA : 10 times max. range current
199.9 mA : 1 A
1.999 A : 3 A
Caution: In circuits where fault currents can exceed the maximum shunt
current, a fast-blow fuse should be installed in series with the input signal.
Otherwise, a slow blow 10 amp fuse is recommended that will allow for
start-up over current situations, while still protecting the instrument.
9. TEMPERATURE COEFFICIENTS :
Current meters Voltmeters
DC: ? 100 PPM/ ° C DC: ? 75 PPM/ ° C
AC: ? 200 PPM/ ° C AC: ? 150 PPM/ ° C
10. ENVIRONMENTAL CONDITIONS :
Operating Temperature : 0° to 60 °C
Storage Temperature : -40° to 80 °C
A CCESSORIES
UNITS LABEL KIT (PAXLBK)
Each meter has a units indicator with backlighting that can be customized
using the Units Label Kit. The backlight is controlled by a DIP switch.
3
Operating and Storage Humidity : 85% max. relative humidity (non-
condensing)
Vibration According to IEC 68-2-6 : Operational 5 to 150 Hz, in X, Y, Z
direction for 1.5 hours, 2g.
Shock According to IEC 68-2-27 : Operational 30 g, 11 msec in 3 directions.
Altitude : Up to 2000 meters
11. RESPONSE TIME TO STEP CHANGE INPUT : 1 sec. nominal
12. READING RATE : 2.5 readings/sec., nominal
13. NORMAL MODE REJECTION : 50 dB 50/60 Hz (DC units only)
14. COMMON MODE REJECTION : 110 dB DC or 50/60 Hz (DC units only)
15. COMMON MODE VOLTAGE (COMM. TO EARTH) : 350 volt peak
16. CERTIFICATIONS AND COMPLIANCES :
SAFETY
UL Recognized Component, File #E179259, UL61010A-1, CSA C22.2
No. 61010-1
Recognized to U.S. and Canadian requirements under the Component
Recognition Program of Underwriters Laboratories, Inc.
UL Listed, File #E137808, UL508, CSA C22.2 No. 14-M95
LISTED by Und. Lab. Inc. to U.S. and Canadian safety standards
Type 4X Enclosure rating (Face only), UL50
IECEE CB Scheme Test Report #04ME11209-20041018
Issued by Underwriters Laboratories, Inc.
IEC 61010-1, EN 61010-1: Safety requirements for electrical equipment
for measurement, control, and laboratory use, Part 1.
IP65 Enclosure rating (Face only), IEC 529
ELECTROMAGNETIC COMPATIBILITY:
Emissions and Immunity to EN 61326: Electrical Equipment for Measurement,
Control and Laboratory use.
Immunity to Industrial Locations:
Electrostatic discharge EN 61000-4-2 Criterion A
4 kV contact discharge
8 kV air discharge
Electromagnetic RF fields EN 61000-4-3 Criterion B
10 V/m
Fast transients (burst) EN 61000-4-4 Criterion B
2 kV power
2 kV signal
Surge EN 61000-4-5 Criterion A
1 kV L-L,
2 kV L&N-E power
RF conducted interference EN 61000-4-6 Criterion A
3 V/rms
Voltage dip/interruptions EN 61000-4-11 Criterion A
0.5 cycle; 40 % variation
Emissions:
Emissions EN 55011 Class B
Notes:
1. Criterion A: Normal operation within specified limits.
2. Criterion B: Temporary loss of performance from which the unit self-
recovers.
17. CONNECTIONS : High compression cage-clamp terminal block
Wire Strip Length: 0.3" (7.5 mm)
Wire Gage: 30-14 AWG copper wire
Torque: 4.5 inch-lbs (0.51 N-m) max.
18. CONSTRUCTION : This unit is rated for NEMA 4X/IP65 outdoor use.
Installation Category II, Pollution Degree 2. One piece bezel/case. Flame
resistant. Panel gasket and mounting clip included.
19. WEIGHT : 0.65 lbs. (0.24 Kg)
EXTERNAL CURRENT SHUNTS (APSCM)
To measure DC current signals greater than 2 ADC, a shunt must be used. The
APSCM010 current shunt converts a maximum 10 ADC signal into 100.0 mV.
The APSCM100 current shunt converts a maximum 100 ADC signal into 100.0
mV. The continuous current through the shunt is limited to 115% of the rating.
相关PDF资料
PAXLIT00 METER AC CURRENT 5A 3 1/2-DIGIT
PAXLPV00 METER PROCESS VOLT 3 1/2-DIGIT
PAXLRT00 METER RTD TEMP 4-DIGIT
PAXLSG00 METER STRAIN GAGE 3 1/2-DIGIT
PAXLTC00 METER THERMOCOUPLE 4-DIGIT
PAXLVA00 VOLTMETER AC 3 1/2-DIGIT
PAXLVD00 VOLTMETER DC 3 1/2-DIGIT
PAXTM100 TIMER DISPLAY 1/8 DIN PRESET 6 D
相关代理商/技术参数
PAXLID00 功能描述:METER DC CURRENT 3 1/2-DIGIT RoHS:是 类别:工业控制,仪表 >> 仪表 - 面板,数字 系列:PAX®LITE 标准包装:12 系列:* 其它名称:Q7072030
PAXLIT00 功能描述:METER AC CURRENT 5A 3 1/2-DIGIT RoHS:是 类别:工业控制,仪表 >> 仪表 - 面板,数字 系列:PAX®LITE 标准包装:12 系列:* 其它名称:Q7072030
PAXLPT00 功能描述:METER PROCESS TIME 6-DIGIT RoHS:是 类别:工业控制,仪表 >> 定时器 系列:PAX®LITE 标准包装:10 系列:- 计时范围:- 工作模式:累积 输出类型:- 电源电压:4.5 V ~ 10 V 端接类型:PCB 引脚 显示器类型:无显示器 其它名称:2001PC-001 5VDCQ1273012Q1443992
PAXLPV00 功能描述:METER PROCESS VOLT 3 1/2-DIGIT RoHS:否 类别:工业控制,仪表 >> 仪表 - 面板,数字 系列:PAX®LITE 标准包装:12 系列:* 其它名称:Q7072030
PAXLR000 功能描述:METER RATE INDICATION 6-DIGIT RoHS:是 类别:工业控制,仪表 >> 计数器 系列:PAX®LITE, PAXLR 其它有关文件:Declaration of Conformity 标准包装:1 系列:99766 计数速率:25Hz 数字/字母数:5 输入类型:机电式脉冲 输出类型:- 电源电压:24V 显示器类型:十进制拨轮
PAXLRT00 功能描述:METER RTD TEMP 4-DIGIT RoHS:是 类别:工业控制,仪表 >> 仪表 - 面板,数字 系列:PAX®LITE 标准包装:12 系列:* 其它名称:Q7072030
PAXLSG00 功能描述:METER STRAIN GAGE 3 1/2-DIGIT RoHS:否 类别:工业控制,仪表 >> 仪表 - 面板,数字 系列:PAX®LITE 标准包装:12 系列:* 其它名称:Q7072030
PAXLT000 制造商:Red Lion Controls 功能描述:METER, TC/RTD TEMP WITH DUAL RELAY 制造商:Red Lion Controls 功能描述:TC/RTD TEMP WITH DUAL RELAY